Almag-03 magnetotherapeutic device (Diamag)

Almag-03 magnetotherapeutic device (Diamag)

select a flag to translate

AfrikaansAlbanianArabicArmenianAzerbaijaniBasqueBelarusianBulgarianCatalanChinese (Simplified)Chinese (Traditional)CroatianCzechDanishDutchEnglishEstonianFilipinoFinnishFrenchGalicianGeorgianGermanGreekHaitian CreoleHebrewHindiHungarianIcelandicIndonesianIrishItalianJapaneseKoreanLatvianLithuanianMacedonianMalayMalteseNorwegianPersianPolishPortugueseRomanianSerbianSlovakSlovenianSpanishSwahiliSwedishThaiTurkishUrduVietnameseWelshYiddishBengaliBosnianKhmerLaoMaoriMongolianNepaliSomali
$371.41



Share
 

The device is intended for physiotherapy with a low-frequency, low-intensity pulsed magnetic field of brain diseases in medical, medical and preventive institutions, as well as at home on the recommendation of a doctor.
The device consists of a control unit and two emitters. Each emitter contains 6 inductors. At the edges of each emitter there are special fasteners for straps.
The front panel of the control unit contains controls and indications
The device generates two types of pulsed magnetic fields - traveling and stationary.
A running field is a field in which all inductors of the emitter are sequentially excited from the 1st inductor to the 6th according to a cyclic law. The traveling field, depending on the program, is formed by single pulses or “packs” of pulses.
A stationary field is a field in which all inductors are simultaneously excited.

The device is operational when powered from an alternating current network with a frequency of 50 Hz, voltage 220V

Parameters and characteristics of pulsed magnetic fields:
a) types of field:
- “running”, in which all inductors of the emitters are sequentially excited from the 1st inductor to the 6th according to a cyclic law (programs No. 1, No. 2, No. 3);
- “stationary”, in which simultaneous excitation of all inductors of the emitters occurs (program No. 4).
b) frequency of excitation of emitter inductors with single pulses:
- 7 pulses/s (program No. 2).
The relative deviation of the frequency value is within ±5%.
c) the excitation frequency of the emitter inductors in bursts of pulses automatically changes within the limits:
- from 1 to 5 pulses/s (programs No. 1, No. 4);
- from 5 to 15 pulses/s (programs No. 3).
The relative deviation of extreme frequency values is no more than ±10%.
d) the time during which the frequency of repetition of “packs” of excitation pulses changes from the maximum value to the minimum and back:
- 126±10 s for program No. 3;
- 612±30 s for programs No. 1 and No. 4;
e) repetition rate of excitation pulses within each packet:
- 30 pulses/s (program No. 3);
- 7 pulses/s (program No. 1, No. 4).
Relative frequency deviation within ±5%;
f) values of the amplitude of magnetic induction on the surface of the inductors:
- 10 mT (programs No. 1, No. 2, No. 3);
- 8 mT (program No. 4).
The absolute deviation of the amplitude value of induction (B) is within ±[0.2B+0.6] mT.

Indications
- consequences of a cerebrovascular accident;
- transient ischemic attack,
- chronic cerebral ischemia;
- migraine (hemicrania), migraine neuralgia;
- mixed anxiety-depressive disorders;
- osteochondrosis of the cervical spine with symptoms of cephalgia, cranialgia;
- chronic iridocyclitis.
Additional applications:
- Parkinson's disease - prevention of disease progression;
- sleep disorders.

Contraindications
- malignant neoplasms;
- severe heart rhythm disturbances (atrial fibrillation, paroxysmal tachyarrhythmia);
- presence of an artificial heart pacemaker;
- infectious diseases in the acute stage and fever of any etiology;
- respiratory failure;
- acute purulent processes on the head;
- active tuberculosis process;
- aneurysm of the heart, aorta and large vessels;
- tendency to bleeding;
- mental and alcoholic agitation;
- thrombocytopenia, bleeding and coagulopathy;
- systemic blood diseases;
- thyrotoxicosis;
- pregnancy.
Attention! The presence of metal dentures is not a contraindication to treatment.

Product added to wishlist